If you own a rental in Perth, you’ve probably heard a few versions of “the rules”. Some come from a property manager, some from a mate who rents out a unit, and some from websites that make things sound scarier (or simpler) than they are.
At Brillare Electrical, we spend a lot of our week inside rental homes, between tenancies, before sales and when something has gone wrong. We also keep a close eye on what Building and Energy and Consumer Protection publish, because the rules do get updated. So we want to give you the honest version: what the law actually requires, what’s simply good practice, and what’s myth.
The good news? WA’s legal must-haves for rental electrical safety are fairly short. The catch is that they apply before a tenant moves in, and getting them wrong can cost you far more than doing them right.
The short version: two things must be in place before you lease

Under WA law, a rental home needs two pieces of electrical safety gear sorted before it can be offered for lease:
- At least two RCDs (safety switches) on the switchboard, protecting the power points and lights.
- Compliant smoke alarms that are mains powered (hardwired), in working order and less than 10 years old.
That’s the legal core. Everything else in this article is about getting those two right, understanding who does what, and knowing when it pays to go further. The Consumer Protection rental home safety page lists both requirements alongside your other safety duties as a landlord.
RCDs: the two-switch rule, explained
What is an RCD? A residual current device (often called a safety switch) watches the electricity flowing through a circuit. If some of it leaks somewhere it shouldn’t, such as through a person touching a faulty appliance, it cuts the power in a fraction of a second. Horizon Power describes them switching off within 10 to 50 milliseconds. It’s the difference between a nasty fright and something far worse.
Why two, not one? If a home has a single RCD and it trips, the whole house can go dark, including the lights you need to find your way to the switchboard. Splitting the protection across two RCDs means one fault doesn’t knock out everything.
What the rule actually says. WA rentals must have at least two RCDs protecting the final sub-circuits that feed power points and lighting. A “final sub-circuit” is simply one of the individual circuits coming off your switchboard, usually labelled something like “Kitchen GPOs” or “Lights 1”. The rules also say:
- No single RCD can protect more than three of those circuits.
- If the home has two or more lighting circuits, they must be split between the RCDs, so a single trip never leaves the whole house without light.
When it applies. The landlord must have the two RCDs installed before the property is offered for lease. The same two-RCD minimum applies before selling a home and in all homes built after 2000, which is why it often comes up in a pre-sale electrical inspection too.
From our experience: older Perth switchboards with ceramic fuses often have no room for extra RCDs, so meeting the rule can mean a switchboard upgrade rather than just adding switches. It’s worth knowing that before you list the property, not the week before a tenant arrives.
Testing every three months. Each RCD has a “T” or test button. Pressing it should trip the switch straight away; then you simply flip it back on. Building and Energy recommends this every three months, and in a rental the tenant is expected to do it and tell you in writing if an RCD doesn’t trip. A faulty RCD must be replaced immediately. Building and Energy’s RCD testing guide walks through it step by step, and is a handy link to include in your tenant welcome pack.
Smoke alarms: hardwired, working and under 10 years old
Before a home is rented, sold or hired out (short-stay rentals included), its smoke alarms must be:
- installed in line with the building laws
- less than 10 years old
- in working order
- permanently connected to mains power, meaning hardwired into the home’s electrical system rather than running on a battery alone
Who can install them. Mains-powered smoke alarms must be installed by a licensed electrical contractor. This isn’t a weekend DIY job, and a handyman screwing a battery unit to the ceiling won’t make a rental compliant.
The battery-alarm exception. There is one, but it’s narrow. A battery-powered alarm is only allowed where there’s no hidden space to run wiring, such as a concrete ceiling or a flat roof. Even then, it must have a 10-year battery that can’t be removed. If your home has a normal roof space, expect hardwired alarms to be required.
Do the alarms need to be interconnected? Interconnected alarms talk to each other: when one detects smoke, they all sound. Homes approved or built before 1 May 2015 don’t need interconnected alarms when rented. Homes built or substantially renovated since then generally do, under the building rules they were approved under. We still recommend interconnection for any home with bedrooms spread apart, because an alarm in the hallway is easy to sleep through behind a closed door.
What about the newer Australian Standard? You may hear that every alarm must meet the latest version of the smoke alarm standard (AS 3786). The standard is updated from time to time, but a change applies to new installations. It doesn’t automatically make an existing, compliant, in-date alarm illegal. The practical trigger for most landlords is the 10-year age limit, which is printed on the alarm.
If you’d like the detail on what’s changing for WA homes, our WA smoke alarm compliance 2027 guide covers it, and our smoke alarm installation page explains how we fit them.
Myth-busting: there’s no mandatory “landlord safety certificate” in WA
This is the one we hear most, and it’s worth clearing up. Some websites claim WA landlords must hold a periodic “electrical safety certificate” or inspection report before every lease. That isn’t what the law says.
The legal duty in WA is that compliant RCDs and smoke alarms are in place before each lease. There’s no statutory requirement for a fresh inspection with every new tenant, and no set inspection cycle. Victoria does require periodic electrical safety checks in rentals, which is likely where some of the confusion comes from, but WA hasn’t adopted that rule.
Two real documents do exist, and they’re often mixed up. Both relate to electrical work being done, not to an inspection:
| Document | What it is | Who gets it | Deadline |
|---|---|---|---|
| Notice of Completion | The contractor’s formal notice that notifiable electrical work (such as new RCDs or a switchboard upgrade) is finished | The network operator, usually Western Power | Within 3 days of finishing the work |
| Electrical Safety Certificate | Confirms the completed work has been tested and is safe | The person who asked for the work, often you or your property manager | Within 28 days |
So if we install your RCDs or hardwired smoke alarms, you’ll receive an Electrical Safety Certificate for that work. Keep it. It’s excellent evidence that the job was done properly, even though it isn’t a “licence to lease”.
Our honest take: a regular compliance check is genuinely good practice, and we’ll explain why below. But we’d rather you book one because it protects your tenants and your investment, not because someone told you it’s legally mandatory when it isn’t.
Related: Electrical compliance and regulatory standards.
What happens if you get it wrong
We don’t like scare tactics, but the numbers help put the cost of compliance in perspective:
| Breach | Possible penalty |
|---|---|
| Renting out a home without a compliant smoke alarm | A $1,000 infringement notice, and a fine of up to $5,000 for a landlord offering the home for hire |
| Breaching the electrical safety rules, such as the RCD requirement | Up to $15,000 for individuals and $100,000 for companies |
Smoke alarm rules sit under the Building Regulations 2012, so enforcement usually comes from your local council. RCD rules are electrical safety law, overseen by Building and Energy.
The fines aren’t the biggest risk, though. Consumer Protection notes that a landlord owes a duty of care to tenants and their guests, and may be sued for negligence if someone is hurt because the home isn’t safe. Compared with that, two RCDs and a set of in-date alarms are a very small outlay.
Who does what: landlord, tenant and property manager
Rental safety is shared, but the buck stops with the owner.
| Task | Landlord | Tenant | Property manager |
|---|---|---|---|
| Install two RCDs and compliant smoke alarms before leasing | Responsible | — | Arranges the electrician |
| Replace alarms before they reach 10 years old | Responsible | — | Tracks expiry dates |
| Push-button test RCDs | Replaces faulty RCDs immediately | Every three months | Reminds tenants |
| Test smoke alarms | Keeps them compliant | Monthly | Includes in routine inspections |
| Replace a 9-volt alarm battery | If hard to reach (high ceilings) | If easy to reach | — |
| Report faults or missing RCDs | Fixes promptly | In writing to the manager or landlord | Passes on and books repairs |
If a tenant notices the two RCDs haven’t been installed, they’re encouraged to write to the property manager, and can contact Building and Energy if it still isn’t done. In other words, an uncompliant switchboard tends not to stay a secret.
Hazards that need action straight away
Some warning signs point to a fault in the supply to the home, not just inside it. If a tenant reports any of these, treat it as urgent:
- an electric shock or tingle from a tap, shower, sink or other metal fixture
- lights dimming or brightening for no obvious reason
The tenant (or you) should report it immediately to Western Power on 13 13 51 and to the property manager. Once the network side is checked, a licensed electrician should inspect the home’s wiring. Building and Energy’s electrical safety for renting and hiring factsheet is a good one-page summary to share with tenants.
When it matters most: the moments to check
Compliance isn’t a one-off box to tick. In our experience, problems surface at a few predictable points in a rental’s life:
- Before you first lease the property. This is the legal deadline for both RCDs and smoke alarms. If you’ve just bought an older home to rent out, check the switchboard early, because adding RCDs can mean upgrading the board.
- Between tenancies. The law requires compliance before each lease. The vacant week between tenants is the easiest time to test everything, replace ageing alarms and fix small faults without disturbing anyone.
- When an alarm nears its 10th birthday. Check the date on each alarm. If any will pass 10 years during the next lease, replacing them now saves a mid-tenancy call-out.
- After renovations or new appliances. New circuits, a kitchen refit or an added air conditioner can change how circuits are split across your RCDs.
- Before you sell. Two RCDs and compliant smoke alarms are needed before a home changes hands too, so a rental heading to market should be checked first.
Going beyond the legal minimum (and why it pays)
The law sets a floor, not a standard of care. A home can have two working RCDs and in-date alarms and still have a loose connection behind a power point, a scorched light fitting or an overloaded circuit. Those are the faults that turn into emergency call-outs, unhappy tenants and, occasionally, fires.
That’s why we recommend a rental electrical compliance check between tenancies, or at least every couple of years for long-term leases. To be clear, this is our recommendation, not a legal requirement. A typical Brillare rental check covers:
- testing each RCD with proper equipment, not just the push button
- checking circuits are correctly split across the RCDs
- confirming smoke alarm age, location, power supply and interconnection
- a visual check of the switchboard, power points, switches and light fittings
- a written report you can keep with your property records
For property managers. If you look after a rent roll, a consistent process across your properties saves time and protects your landlords. We can work to your inspection schedule, report in a format that suits your files and flag alarms approaching expiry.
Our strata and property management and compliance and safety checks pages go into more detail.
From the field: 300+ rental homes for the WA Department of Communities. Since 2024, Brillare has been a delivery partner to Programmed Facility Management on the Department of Communities’ housing maintenance program. That means reactive and planned electrical work across more than 300 tenanted homes in Perth’s south metro and the South West, many of them home to elderly residents, people with disabilities or people facing disadvantage. Compliance and paperwork have to be right every time at that scale. As Programmed FM’s Subcontractor Relationship Manager put it, “Brillare’s compliance processes are robust, their documentation is reliable.” Read the full case study.
What does compliance cost? Here are typical Perth price ranges for the work landlords most often need, taken from our guide to electrician costs in Perth:
| Job | Typical cost | Typical time |
|---|---|---|
| Safety switch (RCD) installation | $180 to $320 | 45 to 75 minutes |
| Hardwired smoke alarm installation | $200 to $380 per alarm | 60 to 90 minutes |
| Switchboard upgrade | $800 to $2,200 | 2 to 5 hours |
Older homes with ceramic fuses or poor earthing usually sit at the higher end, because that work has to be fixed before new RCDs can safely go in.
On cost generally: Brillare has a zero-dollar call-out fee, a lifetime workmanship warranty and payment plans for larger jobs like switchboard upgrades.
Keeping your rental safe, compliant and stress-free
WA’s rental electrical rules are simpler than the internet suggests: two RCDs, hardwired smoke alarms under 10 years old, and both in place before every lease. The hard part is staying on top of it across tenancies, ageing alarms and changing standards.
That’s where we come in. Our team works to the WA Electrical Requirements, the rulebook every WA electrician follows, and we keep track of regulator updates so you don’t have to. When something changes that affects Perth landlords, we’ll tell you in plain English.
Brillare Electrical is a licensed electrical contractor (EC13482). Every job comes with a zero-dollar call-out fee and a lifetime workmanship warranty.
Ready to check your rental? Get a free quote, call 08 9415 0762 or book online, and we’ll make sure your property is ready for its next tenant.
Frequently asked questions
Do I need an electrical safety certificate to rent out my property in WA?
No. WA law requires two RCDs and compliant smoke alarms before each lease, but there’s no mandatory periodic inspection certificate. You will receive an Electrical Safety Certificate whenever a licensed electrician completes electrical work, and it’s good evidence to keep.
How many circuits can one RCD protect?
No more than three final sub-circuits per RCD. If the home has two or more lighting circuits, they must be split across the RCDs.
My rental only has one safety switch. Can I still lease it?
Not legally. You’ll need at least two RCDs installed before offering the property for lease. On older boards, that may mean a switchboard upgrade.
Can I use battery smoke alarms in my rental?
Only where there’s no hidden space to run wiring, such as a concrete ceiling or flat roof, and only with a non-removable 10-year battery. Otherwise, alarms must be hardwired by a licensed electrician.
How often should RCDs and smoke alarms be tested?
RCDs every three months using the test button. Smoke alarms monthly. In a rental, tenants are expected to do these tests and report faults in writing.
Do I need new smoke alarms for every new tenant?
No. You need alarms that are compliant, working and under 10 years old at the start of each lease. If they meet that, they can stay.
What should a tenant do if they get a shock from a tap?
Stop using it and call Western Power on 13 13 51 straight away, then notify the property manager in writing.